Specifications :
Relative Humidity :
RH Sensing Technology : Polymer based Capacitive sensor
RH Measurement Range : 0% to 100%
RH Accuracy : ±2% @ 25°C for 10 to 90% RH
RH Resolution : 0.01%
RH Repeatability : ±0.1% typical
RH Response time : 4 Secs (t 63%)
RH Long term drift : <0.2 % RH Per year
RH Output : 4-20mA @500 ohms
Temperature :
Temp. Measurement Range : 0 to +70°C
Temp. Accuracy : ± 0.2°C
Temp. Resolution : 0.01 °C
Temp. Repeatability : 0.04 °C typical
Temp. Response time : 2 Secs (t 63%)
Temp. Long term drift : <0.03°C Per year
Temp. Output : 4-20mA @500 ohms
Supply Voltage : 24VDC / 24VAC ±10 %
Operating Temperature : - 25° to +50°C
Enclosure :
Material : Di Cast Aluminum Alloy LM6
Type of Explosion Protection : EEx-d, IEC60079-1:2007
Zone Classification : Suitable for Zone 1 & 2
Gas Group : Suitable for Gas group IIA, IIB & IIC, T6
Ingress Protection : IP66, IEC60529-1:2001
Paint : Epoxy Polyester powder coated
Cable Entry : ½” NPT double compression gland
Probe :
Material : SS304
Dust Screen : SS304
Futuristic FLP Humidity and Temperature Transmitter series TRH01EX02 is designed for use in hazardous areas. It is suitable for Zone classification Zone 1 & 2 and Gas Group IIA,IIB & IIC, T6
Specifications :
Relative Humidity :
RH Sensing Technology : Polymer based Capacitive sensor
RH Measurement Range : 0% to 100%
RH Accuracy : ±2% @ 25°C for 10 to 90% RH
RH Resolution : 0.01%
RH Repeatability : ±0.1% typical
RH Response time : 4 Secs (t 63%)
RH Long term drift : <0.2 % RH Per year
RH Output : 4-20mA @500 ohms
Temperature :
Temp. Measurement Range : 0 to +70°C
Temp. Accuracy : ± 0.2°C
Temp. Resolution : 0.01 °C
Temp. Repeatability : 0.04 °C typical
Temp. Response time : 2 Secs (t 63%)
Temp. Long term drift : <0.03°C Per year
Temp. Output : 4-20mA @500 ohms
Supply Voltage : 24VDC / 24VAC ±10 %
Operating Temperature : - 25° to +50°C
Enclosure :
Material : Di Cast Aluminum Alloy LM6
Type of Explosion Protection : EEx-d, IEC60079-1:2007
Zone Classification : Suitable for Zone 1 & 2
Gas Group : Suitable for Gas group IIA, IIB & IIC, T6
Ingress Protection : IP66, IEC60529-1:2001
Paint : Epoxy Polyester powder coated
Cable Entry : ½” NPT double compression gland
Probe :
Material : SS304
Dust Screen : SS304